AX-GS-ND-V / NO2,0-10ppm POA Qty
AX-GS-ND-VR / NO2,0-10ppm with relay POA Qty
AX-GS-ND-VR2 / NO2,0-10ppm with 2 relays POA Qty
AX-GS-ND-VL / NO2,0-10ppm, LCD POA Qty
AX-GS-ND-VRL / NO2,0-10ppm with Relay, LCD POA Qty
AX-GS-ND-VR2L / NO2,0-10ppm with 2 Relay, LCD POA Qty
 <<  |  <  | OVERVIEW | SPECIFICATION | DATASHEETS        

The AX-GS-ND-V Nitrogen Dioxide Voltage Transmitter provides a linear output signal for NO2 levels from 0-10ppm. The output voltage is configurable for either 0-5Vdc, 2-10Vdc or 0-10Vdc. Options include relay(s) with set trip points and an LCD display. The sensor module uses a plug-in connector, making for easy in-the-field replacement. The unit can be mounted with the cable gland entry pointing up or down.
Product Features
• Monitors NO2 levels over a range of 0 to 10 ppm
• Electrochemical sensing element
• Relay option with jumper set alarm levels
• Easy installation with plug-in connections
• 0-5, 2-10 or 0-10Vdc selectable voltage output
• Open-collector fault output
• Easy maintenance and 2 year exchange sensor option
• 2 year warranty

Power Supply
24Vac ±10%, 100mA maximum or 24Vdc ± 10%, 60mA maximum
Sensor Type
Electrochemical 3-electrode
Output
0-5Vdc, 2-10Vdc or 0-10Vdc at 5mA maximum load
Output Range
0-10ppm
Output Accuracy
±0.2ppm or 5% of reading (whichever is greater) between 0-50˚C
Response time(t90)
<35 Seconds
Long term sensitivity drift
<12% signal drift per year
Relay (option)
SPCO relay, 230Vac 5A (resistive) can be set to trip at 1, 3 or 5 ppm
2 Relay (option)
Two SP relays, 50V 1A (resistive) can be set to trip at 1/2, 3/5 or 5/7ppm
Display (option)
4 digit 9mm high character backlit LCD of reading in ppm
Fault output
Open collector. 30Vdc at 100mA maximum
Typical Coverage Area
700m² or 15m radius
Settling Time
3 minutes after power up
Life Expectancy
>2 years dependant on environment
Ambient Temperature & Humidity
0-50ËšC, 15-90% RH non-condensing
Housing
Flame retardant ABS, IP65, White (optional Black - see order codes)
Dimensions & Weight
92mm diameter x 52mm, 170gms
Terminals
Rising clamp for 0.5-1.5mm²
Country of origin
UK